20
INSTALLER SECTION
Programming
System programming
All system programming resides in the ISH1
Hub. For a six-zone system with ISK1 Basic
Keypads, programming consists only of setting
the doorbell chimes. For a system with ISK2
Advanced Keypads, programming includes
assigning zone and door station labels. For a
system with more than six zones, programming
includes setting hub ID numbers.
The ISH1 Hub has DIP switches for setting the
hub ID number and doorbell chime assignments.
The hub’s firmware contains lists of zone and
door station labels for display on the ISK2
Advanced Keypads. These labels are assigned
by using a connected ISK2 keypad.
With multiple hubs, the label settings are initially
stored in the hub to which the keypad is con-
nected. Upon exiting the programming proce-
dure, the settings are copied to the other hubs.
Hub 1 serves as the master hub for storing all
zone and door label settings. Whenever hub 1 is
powered up, its settings are copied to the other
hubs. Accordingly, hub 1 should be powered up
last whenever the system power is cycled.
Hub ID numbers
In a system with multiple ISH1 Hubs, each hub
must have a unique ID number. This is manually
assigned on the 4-switch HUB ID DIP before the
system is powered up. To assign the ID number,
set switches 1 through 3 as shown in table 1.
Switch 4 enables a programming mode for
updating the system firmware. Leave this switch
in the up position for system operation.
Doorbell chimes
A single 8-switch DIP assigns doorbell chimes
for both door stations. Switches 1 through 3
select the chime for door 1 and switches 5
through 7 select the chime for door 2. There
are 7 chime options, with a setting for no chime
when a separate doorbell system is used. To
select the chimes, set the switches as shown in
table 2.
Fig. 24. DIP switches on ISH1 Hub
Table 1. Hub ID switch settings
Table 2. Doorbell chime switch settings
Hub ID Switch Settings (0 = Down, 1 = Up)
Switches
Hub ID FW*
1 2 3 4
Hub 1 0 0 0 1
Hub 2 0 0 1 1
Hub 3 0 1 0 1
Hub 4 0 1 1 1
Hub 5 1 0 0 1
Hub 6 1 0 1 1
*Switch 4 is for firmware updates
(0 = Update Mode, 1 = User Mode)
Doorbell Chime Switch Settings (0 = Down, 1 = Up)
Switches
Door 1 CV* Door 2
1 2 3 4 5 6 7 8
None 0 0 0 0/1 0 0 0
Chime 1 0 0 1 0/1 0 0 1
Chime 2 0 1 0 0/1 0 1 0
Chime 3 0 1 1 0/1 0 1 1
Chime 4 1 0 0 0/1 1 0 0
Chime 5 1 0 1 0/1 1 0 1
Chime 6 1 1 0 0/1 1 1 0
Chime 7 1 1 1 0/1 1 1 1
*Switch 4 is for chime volume
(0 = Keypad Adjustable, 1 = 50% Keypad Maximum)